NWMUDS:PullPacket

From 3dbrew
Jump to navigation Jump to search

Request[edit]

Index Word Description
0 Header code [0x001400C0]
1 u32 BindNodeID.
2 4-byte aligned MaxOutBufSize >> 2
3 MaxOutBufSize

The following is located 0x100-bytes after the beginning of the above command buffer:

Index Word Description
0 (OutBufSize<<14) | 2
1 Pointer to the output buffer

Response[edit]

Index Word Description
0 Header code
1 Result code
2 Actual data size
3 u16, source NetworkNodeID.
4 (OutBufSize<<14) | 2
5 Pointer to the output buffer

Description[edit]

This loads a previously received individual data frame from state, while connected to the UDS network. This includes all frames received from a node before the node disconnected. The input size must be >= frame_size, otherwise error 0xE10113E9 is returned.

The MaxOutBufSize_wordsize is clamped to 0x172(aka 0x5C8-bytes), but this field isn't really used after that. Instead it just uses MaxOutBufSize, without a size limit.