DSP:ReadPipeIfPossible

Revision as of 22:39, 7 March 2016 by Merry (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

RequestEdit

Index Word Description
0 Header code [0x001000c0]
1 Channel (0 - 7 0:Debug from DSP 1:P-DMA 2:audio 3:binary 4-7: free ?)
2 Peer (0 = from DSP, 1 = from ARM)
3 u16, Size

0x100 byte after the Request header

Index Word Description
0 (Size << 14) | 0x2
1 Buffer

ResponseEdit

Index Word Description
0 Header code
1 Result code
2 u16, Actual read size

ChannelsEdit

Channel 2 (Audio)Edit

Channel 2 returns the DSP DRAM addresses of structures located in the DSP Memory Region. DSP:ConvertProcessAddressFromDspDram can be used to convert these addresses into virtual memory addresses. The list of addresses and the length of the list vary depending on DSP firmware version.

Channel 3 (Binary)Edit

The purpose of channel 3 is unknown. The behaviour of this pipe varies depending on DSP firmware version. Observed behaviours include:

  • doing nothing.
  • echoing what is returned to it.
  • long strings of zeros.