Request[edit]

Index Word Description
0 Header code [0x00220402]
1 Output buffer max size
2-14 Input ScanInputStruct.
15 wlancommID
16 This is the ID also located at offset 0xE in the CTR-generation structure.
17 (Size<<4) | 12
28 Output BeaconDataReply buffer ptr

Response[edit]

Index Word Description
0 Header code
1 Result code

Description[edit]

This is about the same as NWMUDS:StartScan except this only returns already received beacon data, and it can only be used when connected to a network.