LCD Registers
Jump to navigation
Jump to search
Registers
NAME | PHYSICAL ADDRESS | PROCESS VIRTUAL ADDRESS | KERNEL VIRTUAL ADDRESS | WIDTH |
---|---|---|---|---|
REG_LCDCOLORFILLMAIN | 0x10202204 | 0x1ED02204 | 0xFFFD6204 | 4 |
REG_LCDCOLORFILLSUB | 0x10202A04 | 0x1ED02A04 | 0xFFFD6A04 | 4 |
REG_*MAIN registers are used for the top LCD, while SUB is used for the bottom LCD.
REG_LCDCOLORFILL
Bit | Description |
---|---|
7-0 | Red component intensity |
15-8 | Green component intensity |
23-16 | Blue component intensity |
24 | Enable |
31-23 | ? |
When the enable bit is set, the specified solid color is displayed on the LCD instead of the rendered graphics.