There are 4 timers. These timers run at a frequency of 67,027,964.0 ± 2-32 Hz (i.e. exactly half the ARM9 clock frequency).
Registers
Old3DS | Name | Address | Width | Used by |
---|---|---|---|---|
Yes | TIMER_VAL(n) | 0x10003000 + 4*n | 2 | Boot9, Kernel9 |
Yes | TIMER_CNT(n) | 0x10003002 + 4*n | 2 | Boot9, Kernel9 |
TIMER_VAL
Writing to TIMER_VAL loads a starting value for one of the 4 timers, while reading it will show the current timer value.
TIMER_CNT
Bit | Description |
---|---|
1-0 | Prescaler select (0=F/1, 1=F/64, 2=F/256, 3=F/1024) |
2 | Count-up (0=Disabled, 1=Enabled) |
5-3 | Not used |
6 | IRQ enable (0=Disabled, 1=IRQ on timer value overflow) |
7 | Start/Stop (0=Stop, 1=Start) |
Count-up
When count-up is enabled, the timer value will increase every time the previous timer overflows.