Difference between revisions of "PXIDEV:ReadCTRCARD Cmd40"
Jump to navigation
Jump to search
Steveice10 (talk | contribs) m (Steveice10 moved page PXIDEV:ReadCTRCARD to PXIDEV:ReadCTRCARD Cmd40 over redirect) |
Steveice10 (talk | contribs) m |
||
Line 39: | Line 39: | ||
| Result code | | Result code | ||
|} | |} | ||
+ | |||
+ | =Description= | ||
+ | Reads from CTRCARD. The command written to the [[CTRCARD_Registers#CTRCARD_CMD|CTRCARD_CMD]] register is the same as provided, except the highest byte is changed to 0x40. |
Latest revision as of 08:07, 21 January 2016
Request[edit]
Index Word | Description |
---|---|
0 | Header code [0x000101C2] |
1 | Buffer Size |
2 | Sector Count |
3 | u8, SectorSize |
4-7 | Command |
8 | (Size << 8) | 0x4 |
9 | Buffer Pointer |
Response[edit]
Index Word | Description |
---|---|
0 | Header code |
1 | Result code |
Description[edit]
Reads from CTRCARD. The command written to the CTRCARD_CMD register is the same as provided, except the highest byte is changed to 0x40.