=Request=
{| class="wikitable" border="1"
|-
! Index Word
! Description
|-
| 0
| Header code [0x00510040]
|-
| 1
| bool
|}
=Response=
{| class="wikitable" border="1"
|-
! Index Word
! Description
|-
| 0
| Header code
|-
| 1
| Result code
|}
=Description=
This writes to the MCU system-state buffer and updates the SoftwareClosed (formerly LegacyPoweroff) bit.
This is set by LgyBg during graceful reboot (power not *held*) to prompt a "Software closed" screen when the system returns to NATIVE_FIRM. If power was held during a LGY fatal error, this flag is not set.
This is also set when power is pressed in System Settings (as a reboot is enforced there), hence no longer being called "LegacyPoweroff".