Difference between revisions of "PXI Registers"

From 3dbrew
Jump to navigation Jump to search
Line 24: Line 24:
 
| 0x10008000
 
| 0x10008000
 
| 4
 
| 4
 +
|
 +
|-
 +
| style="background: green" | Yes
 +
| PXI_????9
 +
| 0x10008003
 +
| 1
 
|
 
|
 
|-
 
|-
Line 86: Line 92:
 
| R/W
 
| R/W
 
| Enable IRQ from remote CPU  (0=Disable, 1=Enable)
 
| Enable IRQ from remote CPU  (0=Disable, 1=Enable)
 +
|-
 +
| 23
 +
| ?
 +
| ?
 
|}
 
|}
  

Revision as of 03:03, 22 March 2015

Protocol

The communication protocol for normal PXI commands is documented below. The size of cmd_buf is calculated from the cmd_hdr. Total size for command header + buffer must be at most 0x40 bytes, otherwise Process9 will panic.

Request

A11->A9 (u32) pxi_id
A11->A9 (u32) cmd_hdr
A11->A9 (u32[]) cmd_buf

Response

A9->A11 (u32) pxi_id
A9->A11 (u32) cmd_hdr
A9->A11 (u32[]) cmd_buf

Registers

Old3DS Name Address Width Used by
Yes PXI_SYNC9 0x10008000 4
Yes PXI_????9 0x10008003 1
Yes PXI_CNT9 0x10008004 4
Yes PXI_RECV_FIFO9 0x10008008 4
Yes PXI_SYNC11 0x10163000 4
Yes PXI_CNT11 0x10163004 4
Yes PXI_SEND11 0x10163008 4
Yes PXI_RECV_11 0x1016300C 4

The PXI registers are similar to those on DS.

PXI_SYNC

Bit RW Description
0-3 R Data input from PXI_SYNC Bit8-11 of remote CPU (00h..0Fh)
8-11 R/W Data output to PXI_SYNC Bit0-3 of remote CPU (00h..0Fh)
13 W Send IRQ to remote CPU (0=None, 1=Send IRQ)
14 R/W Enable IRQ from remote CPU (0=Disable, 1=Enable)
23 ? ?

PXI_CNT

Bit RW Description
0 R Send Fifo Empty Status (0=Not Empty, 1=Empty)
1 R Send Fifo Full Status (0=Not Full, 1=Full)
2 R/W Send Fifo Empty IRQ (0=Disable, 1=Enable)
3 W Send Fifo Clear (0=Nothing, 1=Flush Send Fifo)
8 R Receive Fifo Empty (0=Not Empty, 1=Empty)
9 R Receive Fifo Full (0=Not Full, 1=Full)
10 R/W Receive Fifo Not Empty IRQ (0=Disable, 1=Enable)
14 R/W Error, Read Empty/Send Full (0=No Error, 1=Error/Acknowledge)