Difference between revisions of "PTM:CheckNew3DS"
Jump to navigation
Jump to search
m (moved PTMSYSM:CheckNew3DS to PTM:CheckNew3DS) |
|
(No difference)
|
Revision as of 17:00, 10 October 2014
Request
Index Word | Description |
---|---|
0 | Header code [0x040A0000] |
Response
Index Word | Description |
---|---|
0 | Header code |
1 | Result code |
2 | u8 output: 0 = original hardware, 1 = New 3DS. |
Description
This command was added with 8.0.0-18.
With the original 3DS PTM module, hard-coded value 0 is written to the output. With the New_3DS PTM module, hard-coded value 1 is written to the output.