IRU:SetBitRate: Difference between revisions
Jump to navigation
Jump to search
| Line 35: | Line 35: | ||
| 3 | | 3 | ||
| 10 | | 10 | ||
| | | 115200 | ||
|- | |- | ||
| 4 | | 4 | ||
| 12 | | 12 | ||
| | | 96000 | ||
|- | |- | ||
| 5 | | 5 | ||
| 16 | | 16 | ||
| | | 72000 | ||
|- | |- | ||
| 6 | | 6 | ||
| 24 | | 24 | ||
| | | 48000 (This is the default for IRU) | ||
|- | |- | ||
| 7 | | 7 | ||
| 32 | | 32 | ||
| | | 36000 | ||
|- | |- | ||
| 8 | | 8 | ||
| 48 | | 48 | ||
| | | 24000 | ||
|- | |- | ||
| 9 | | 9 | ||
| 64 | | 64 | ||
| | | 18000 | ||
|- | |- | ||
| 10 | | 10 | ||
| 96 | | 96 | ||
| | | 12000 | ||
|- | |- | ||
| 11 | | 11 | ||
| 120 | | 120 | ||
| | | 9600 | ||
|- | |- | ||
| 12 | | 12 | ||
| 192 | | 192 | ||
| | | 6000 | ||
|- | |- | ||
| 13 | | 13 | ||
| 384 | | 384 | ||
| | | 3000 | ||
|- | |- | ||
|- | |- | ||
| 14 | | 14 | ||
| 20 | | 20 | ||
| | | 57600 | ||
|- | |- | ||
| 15 | | 15 | ||
| 30 | | 30 | ||
| | | 38400 | ||
|- | |- | ||
| 16 | | 16 | ||
| 60 | | 60 | ||
| | | 19200 | ||
|- | |- | ||
| 17 | | 17 | ||
| 160 | | 160 | ||
| | | 7200 | ||
|- | |- | ||
| 18 | | 18 | ||
| 240 | | 240 | ||
| | | 4800 | ||
|} | |} | ||
The bps listed above is from code in IR module which converts the input value into actual bps, that function is only used with delay code however. | |||
=Description= | =Description= | ||
This sets the current bitrate. Error 0xE0E10FED is returned when the input value is outside of the above range. Error 0xF9610C02 is returned when the I2C code returns an error. | This sets the current bitrate. Error 0xE0E10FED is returned when the input value is outside of the above range. Error 0xF9610C02 is returned when the I2C code returns an error. | ||
Revision as of 21:32, 22 February 2014
Request
| Index Word | Description |
|---|---|
| 0 | Header code [0x00090040] |
| 1 | u8 bitrate value |
Response
| Index Word | Description |
|---|---|
| 0 | Header code |
| 1 | Result code |
Bitrate Values
| Value | Data passed to the function which writes to the IR-I2C registers for this | Bits-per-second / description |
|---|---|---|
| 3 | 10 | 115200 |
| 4 | 12 | 96000 |
| 5 | 16 | 72000 |
| 6 | 24 | 48000 (This is the default for IRU) |
| 7 | 32 | 36000 |
| 8 | 48 | 24000 |
| 9 | 64 | 18000 |
| 10 | 96 | 12000 |
| 11 | 120 | 9600 |
| 12 | 192 | 6000 |
| 13 | 384 | 3000 |
| 14 | 20 | 57600 |
| 15 | 30 | 38400 |
| 16 | 60 | 19200 |
| 17 | 160 | 7200 |
| 18 | 240 | 4800 |
The bps listed above is from code in IR module which converts the input value into actual bps, that function is only used with delay code however.
Description
This sets the current bitrate. Error 0xE0E10FED is returned when the input value is outside of the above range. Error 0xF9610C02 is returned when the I2C code returns an error.